Sign In | Join Free | My chinacomputerparts.com
China Shaanxi Shinhom Enterprise Co.,Ltd logo
Shaanxi Shinhom Enterprise Co.,Ltd
Verified Supplier

8 Years

Home > Split Core Current Transformer >

Split-Core CT SCTK671 Series for Leakage Fire Prevention and Microcomputer Protection

Shaanxi Shinhom Enterprise Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Split-Core CT SCTK671 Series for Leakage Fire Prevention and Microcomputer Protection

  • 1
  • 2
  • 3

Model Number : SCTK671 Series

Payment Terms : T/T

Output : 0-10V or 0-5A

Coil Number : Autotransformer

Price : Negotiation

Accuracy : 0.2、0.5、1.0

Supply Ability : 10000/MONTH

Current range : 5~3000A

MOQ : Negotiation

Delivery Time : 4~8 Weeks

Customizable : Yes

Coil Structure : Toroidal

Packaging Details : Carton

Place of Origin : China

Certification : RoHS

Brand Name : Shinhom

Contact Now

The SCTK671 series split-core current transformer is designed for current measurement and monitoring in new or existing power distribution networks. The product uses a split-core structure that allows quick installation without disconnecting or removing cables or busbars, significantly reducing installation cost and time. The secondary winding has a built-in precision parallel resistor, providing a safe low-voltage output. Epoxy encapsulation ensures excellent insulation performance and vibration resistance. The high-permeability material provides a wide measuring range. Ratio error: ≤±0.2%. Phase angle error: ≤±10 minutes. Dielectric strength: 2.5KV/1mA/1 minute. It is widely used in electrical fire monitoring, leakage fire prevention, electromagnetic relay protection, and microcomputer protection applications.

Features:
  • Split core CT current transformer
  • Test range: 5 to 3000A AC input, output of 0-10V(AC) or 0-5A
  • Using epoxy resin filling and good seismic performance
  • Use punched way, easy to install
  • Using high permeability material, wide measurement range
  • Small volume, beautiful appearance generous, flexible use
  • It can save time and the installation costs
Applications:
  • Electrical fire monitoring
  • Leakage fire prevention system
  • Electromagnetic relay protection
  • Microcomputer protection and so on.
Electrical Parameter
Frequency50-400Hz
Rated Input5A-3000A
Measuring range5%In-130%In
Rated Output0-10V(AC) or 0-5A
Ratio≤ ± 0.2%
Phase angle≤ ±10min
Dielectric strength2.5KV/1mA/1min
Insulation ResistanceDC500V/100MΩmin
Mechanical Parameter
CasePC /UL94-V0
BobbinPBT
CoreSilicon steel
Internal structureEpoxy
ConstructionTie
Operating Temp-25℃~+75℃
Operating Humidity≤85%
Output ConnectionUL101522AWGWire(twinstedwire)2.5m
Type selection
P/NRated Input (A)Output (mA/V)AccuracyDimensions(mm)
ØABCDEFGHØ1Ø2
SCTK671A-025

5-400A

(5,100,400A)

0-200mA

0-10V

0.2,0.5,1.0

25807522567353211755
SCTK671A-045

50-1000A

(50,400,1000A)

0-500mA

0-10V

0.2,0.5,1.045108107267110074241355
SCTK671A-065

100-1500A

(100,1000,1500A)

0-500mA

0-10V

0.2,0.5,1.065128127269112094271755
SCTK671A-080

500-2000A

(500,1500,2000A)

0-500mA

0-10V

0.2,0.5,1.0801441442897134104271755
SCTK671A-100

800-3000A

(800,2500,3000A)

0-600mA

0-10V

0.2,0.5,1.010017417430126162120271755
Split-Core CT SCTK671 Series for Leakage Fire Prevention and Microcomputer Protection

Notes: Product specifications can be customized

FAQ
Q: Does the split-core current transformer require power-off or cable removal during installation?

A: No. The SCTK671 series uses a split-core structure with a core that opens and closes. It can be installed without disconnecting or removing any cables or busbars. It is especially suitable for retrofit projects and applications where power cannot be turned off, significantly reducing installation costs and time.

Q: What is the function of the built-in precision resistor?

A: The secondary winding has a built-in precision parallel resistor. It converts the current signal directly into a safe low-voltage output (0-10V), eliminating the need for external sampling resistors. This simplifies installation, improves safety, and saves component costs and installation space.

Q: What are the advantages of epoxy potting?

A: Epoxy resin potting provides excellent insulation, moisture-proof, dust-proof, and corrosion protection, while also enhancing the product's vibration resistance. The completely enclosed structure ensures long-term stable operation of the transformer in various harsh environments.

Q: How to apply for samples? What is the lead time?

A: You can submit a sample application through our website or email. Please provide your company information and target model. Samples are free of charge and will be shipped within 3-5 working days. Mass order lead time is generally 2-8 weeks.


Product Tags:

Split Core Current Transformer for leakage prevention

      

Split Core CT for microcomputer protection

      

SCTK671 Series current transformer

      
China Split-Core CT SCTK671 Series for Leakage Fire Prevention and Microcomputer Protection factory

Split-Core CT SCTK671 Series for Leakage Fire Prevention and Microcomputer Protection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shaanxi Shinhom Enterprise Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)